Remote Temperature Sensor Port MC1.5.3.81-2L
Remote Battery Voltage Sense Port MC1.5.3.81-2L
CAN BUS Port MC1.5.3.81-4L
Ethernet Port RJ45
Serial RS-232 Port DB9, male connector
PARAMETRY PRACY:
Charging Stages MPPT,Boost / Equalize,Float
Temp. Compensation Range -25C ~ +55C
Temp. Compensated Setpoints Equalize,Boost,Float,LVD
Ustawienia dla baterii: żelowychKwasowychAGM-bezobsługowych
Equalize Duration TimeBRAK60~180Munuts60~180 minuts
Boost Duration Time:60~180minuts dla wszystkich
Over Limit Voltage:
Upper limit: 17V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit: 15V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default: 16V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Charging Limit Voltage:
Upper limit: 16V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:14V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:15.5V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Over Voltage Reconnect Voltage:
Upper limit:16V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:14V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:15V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Equalize Charging Voltage:
Gel-NO Upper limit:15.2V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Gel-NO Lower limit:14.2V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Gel-NO Default: Default: 14.6V ∕ 12V; ×2 ∕ 24V; 14.8V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V ×3 ∕ 36V; ×4 ∕ 48V
Boost Charging Voltage:
Upper limit:15V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:13.8V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default: Default: Default:
14.2V ∕ 12V; ×2 ∕ 24V; 14.4V ∕ 12V; ×2 ∕ 24V; 14.6V ∕ 12V; ×2 ∕ 24V;
×3 ∕ 36V; ×4 ∕ 48V ×3 ∕ 36V; ×4 ∕ 48V;×3 ∕ 36V; ×4 ∕ 48V
Float Charging Voltage:
Upper limit: 14.2V ∕ 12V;×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit: 13.2V ∕ 12V;×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default: 13.8V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Boost Reconnect Charging Voltage:
Upper limit: 13.5V ∕ 12V;×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:12.7V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:13.2V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Low Voltage Reconnect Voltage:
Upper limit:13.2V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:12V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:12.6V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Under Voltage Warning Reconnect Voltage:
Upper limit:12.6V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:11.8V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:12.2V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Under Voltage Warning Voltage:
Upper limit:12.4V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:11.6V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:12V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Low Voltage Disconnect Voltage:
Upper limit:11.8V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:10.5V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:11.1V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Discharging Limit Voltage:
Upper limit:11V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Lower limit:10.5V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Default:10.8V ∕ 12V; ×2 ∕ 24V; ×3 ∕ 36V; ×4 ∕ 48V
Temperature Compensation Coefficient: (TEMPCO)*
Upper limit: -9mV / C / cell (25C ref.)
Lower limit: -0mV / C / cell (25C ref.)
Default: -5mV / C / cell (25C ref.)
Mechanical |
ET2415N |
Overall |
206x203x105mm |
Mounting |
150x193mm |
Terminal |
35mm2 |
Net Weight |
2.60kg |
Mounting hole |